MULTIMETERS

Model
Function
Lowest Range
Highest Range
No. of Ranges
Input Impedance
Basic Accuracy
DC Output
Power Frequency
Remarks
MV-852A
DC Volts
-10-0-+10
µV
-1 -0- +1 kV
17
Voltmeter
10MegW- Lowest Range
to
100MegW -Highest Range
± 1%
± 2%
0 - ±1 V@FS
0 - ±mA
Adjust.
45-1000Hz
Center Zero Meter
Line Operated
MV-952A
DC Amps
-10-0-+10
pA
-10 -0- +10 mA
19
Center Zero Meter
Line or Battery
MV-753A
DC Volts
-10-0-+10
µV
-1 -0- +1 kV

M753A
9

10

6

M853A
& M953A
17

19

10
Voltmeter
10MegW - Lowest Range
to
100MegW -Highest Range
± 1%
± 2%
0 - ± V@FS
0 - ±mA
Adjust.
4 Digit Readout
Line Operated
MV-853A
DC Amps
-10-0-+10
pA
-10 -0- +10 mA
Analog Readout
Line Operated
MV-953A
DC Null
-10-0-+10
µV
-.3 -0- +3V
Analog Readout
Line Operated

MV-864A

MV964A
DC Volts
0-100µV
0-1000V
15
Voltmeter
10MegW - Lowest Range
to
200MegW -Highest Range
± 1%
0 - ± V@FS
0 - ±mA
Adjust.
Left Zero Meter
Line Operated
DC Amps
0-100nA 0-1A
15
± 2%
Ohms
x10 Midscale x100MeqW
9
± 5%
Left Zero Meter
Line or Battery

MV-873A

MV-973A
DC Volts
0-3mV
0-1000V
12
DCV: 100 MegW Max
        10 MegW Min
ACV: 10MegW, 50pF
RFV: 200KW, 2.2pF
± 1%

MV873A
Line Operated
click here for special Note #12

MV973A
Line or Battery
click here for special Note #12

AC/DC Amps
0-3µA
0-300mA
11
± 2%
AC Volts
0-3mV
0-300V
11
± 2%
RF Volts
0-3mV
0-10V
8
± 3%
Ohms
x10
x100Meq W
9
± 5%